TOP OF THE LINE: FOLLETT REF5P-00-00 UNDERCOUNTER FRIDGE LAB BAR 120V FREE SHIP
TOP OF THE LINE: FOLLETT REF5P-00-00 UNDERCOUNTER FRIDGE LAB BAR 120V FREE SHIP
This listing is for a Great Operational condition, high end, top of the line: FOLLETT REF5P-00-00 PERFORMANCE PLUS UNDERCOUNTER FRIDGE, 120v as can be seen in the pictures.
Came from a Federal University and is in Perfect Operational Condition!
Includes all the original Stainless Steel racks as can be seen in the pictures.
ORIGINAL PRICE OVER US$ 3.800,00 as can be seen by GOOGLING the following link: follettice.com/sites/default/files/2018-04/REF_IOSMan_REF4P5P_Touchscreen_Before%20K25542_01041755R08.pdf
Operation
The temperature control board and probe indicate when the refrigeration system is required to turn on and off.
The refrigeration system removes heat from the cabinet interior and rejects it to the surrounding room air.
When the cabinet interior temperature rises above the controller cut-in temperature, the controller turns the refrigeration system on. The controller energizes the evaporator fan and solid-state control relay which energizes the condensing unit. The compressor uses a current-style starting relay and a starting capacitor to start the compressor motor.
When the cabinet interior falls below the predetermined cut-out temperature, read by the P1 (control probe), the controller de-energizes the solid state compressor relay and condenser fan motor. The additional evaporator fan run-time is dependent upon the delay setting programmed within the controller menu.
Any accumulated frost on the evaporator coils melts during the off cycle. The condensate drains out of the unit to the condensate tray to the left of the condensing unit. The heat from the condensing unit evaporates any condensate in the drain pan.
Temperature Control
The temperature control system is preset by the factory to maintain a cabinet temperature of 3.3 – 5.5 C
(38 – 42 F). If desired, the set-point temperature can be raised as high as 10 C (50 F) by following the instructions in Controller Operation on page 8 for changing the temperature set point. The 2.2 C differential will be maintained regardless of the controller set point.
Defrosting
Performance Plus undercounter refrigerators do not require manual defrosting. The unit cooler defrosts automatically when the condensing unit is in the OFF cycle and during an off time defrost every 8 hours. The defrost will terminate when the evaporator temperature reaches 3.3 C (38 F) or after 30 minutes.