SHIMADZU DOUBLE BEAM AA-6200 ATOMIC ABSORPTION SPECTROPHOTOMETER 90 DAY WARRANTY
SHIMADZU DOUBLE BEAM AA-6200 ATOMIC ABSORPTION SPECTROPHOTOMETER 90 DAY WARRANTY
This listing is for a Great Operational Condition SHIMADZU DOUBLE BEAM AA-6200 ATOMIC ABSORPTION SPECTROPHOTOMETER as can be seen in the pictures.
IMPORTANT: SOFTWARE IS NOT INCLUDED WITH THIS EBAY SALE SINCE THIS EBAY SALE DOES NOT INCLUDE THE COMPUTER NEEDED TO RUN THIS UNIT!!!
Picture is of the actual item buyer will receive, we took pictures in two different locations that's why some pictures have different light contrast from one another but the unit is exactly the same.
FREE SHIPPING TO ANY CONTINENTAL USA BUSINESS LOCATION WHERE BUYER CAN UNLOAD IT OFF THE DELIVERY FREIGHT TRUCK!
This unit was recently removed from service from a Federal University which took excellent care of it and that is why it is in such great condition.
Technical Information in Italics Blue below was taken from Manufacturer's website:
Equipment Description - Purpose of Use for Shimadzu AA-6200 Atomic Absorption Spectrophotometer.
Atomic absorption spectroscopy is used to detect trace amounts of specific elements in solution to a high degree of precision. The sample passes through an acetylene-air flame, upon which it is atomized. This collection of atoms contains mostly atoms in the ground state and very few that have been excited to a higher energy state by the flame. An element-specific lamp that produces light at an extremely narrow wavelength shines upon the collection of atoms in the ground state and the absorbance is measured. The concentration of the sample is then calculated using Beer's law from a calibration curve of standard solutions of known concentration.
Shimadzu's double beam AA-6200 atomic absorption spectrophotometer combines high performance with affordability. The double beam system provides the superior baseline stability expected from high-performance optical systems at an affordable price. A compact system, the AA-6200 uses some of the smallest bench space of an atomic absorption spectrophotometer in the world. In spite of its compactness, the performance and capability are superior.
Analysis of samples is relatively fast, compared to UV-vis spectroscopy. The path length in an AAS is also comparatively long (between 10 and 15 cm), which maximizes the accuracy of detection of trace amounts of analyte.
Relatively large sample amounts (around 1 to 2 mL) are required for analysis.
Equipment Details
Manufacturer: Shimadzu
Model: AA-6200
Optics: Double Beam (chopper mirror)
Monochromator: Aberration corrected Czerny-Turner monochromator Holographic grating (1,600 lines/mm)
Wavelength range: 190-900 nm Automated wavelength selection
Slit: 0.2nm, 0.7 nm Manual setting
Background Correction: D2-Lamp method
Lamp Turret: 2-lamps simultaneously lit (manual turret)
Lamp Mode: Emission, Non-BGC, BGC-D/2
Frequency: 100Hz
Nebulizer: Nebulizer integrated impact bead and jacket tip Pt/Ir capillary
Chamber: Polypropylene
Burner: Fixed back/forward position and burner height, (Simply switching of Air/C2H2 and N2O/ C2H2 burner), Titanium 10cm slot burner (Optional high temperature burner)
Gas Control: Manual setting of flow rate, Automatic Air/ N2O switching system
Safety: Gas pressure monitoring to prevent flashback, Automatic flame monitoring, Safety interlock for misuse of burner, Automatic flame extinguish when power failure
Ignition: Push ignite button
Power requirements: AC220V, 230V, 50/60Hz, 300 VA, (Requires transformer for AC115V), (Certification of CE marking)
Ambient temperature and humidity range: Temperature: 10~35°C, Humidity: 45~80% (but less than 70% if temperature is over 30°C.
This item is heavy, approx 55 lbs.
FREE CONTINENTAL USA SHIPPING!!!!
INTERNATIONAL BUYERS PLS CONTACT US FOR SHIPPING QUOTE!!!
Stock # 230503
Couldn't load pickup availability
Out of stock
View full details