QIAGEN GSD-501 RLS DETECTION & IMAGING INSTRUMENT FREE SHIP
QIAGEN GSD-501 RLS DETECTION & IMAGING INSTRUMENT FREE SHIP
This listing is for a QIAGEN GSD-501 RLS DETECTION & IMAGING INSTRUMENT as can be seen in the pictures.
This GSD-501 RLS DETECTION & IMAGING INSTRUMENT came from a Federal University and has been fully tested by the university where it came from to perform at factory specifications before being shipped.
Technical information in Blue Italics below was taken from manufacturer's website:
tools.thermofisher.com/content/sfs/brochures/1363_Profile_RLS_GSD_501_Reader.pdf
GSD-501 RLS DETECTION & IMAGING INSTRUMENT
The GSD-501 is a fully automated, high precision
detection and imaging instrument designed for use with
ultra-sensitive Resonance Light Scattering (RLS) Technology.
The GSD-501 consists of white light source illumination,
a 16-bit CCD camera, filters for up to 8-color detection
and high speed imaging capabilities for a wide variety of
analytical bioassays and test
formats in a plug & play
system. All images and data
produced by the GSD-501
are in an open source file
format for the end-user to
manipulate freely.
ULTRA-SENSITIVE, REPRODUCIBLE, MULTI-ANALYTE DETECTION
16-Bit CCD Camera Captures Digital Images at 5 µm or 10 µm Resolution with a Dynamic
Range of 3 Logs - 4 Logs
Simple White Light Illumination Projected Through 2 x 8 Position Filter Wheels Enables
Detection of Multiplex Assays
Powerful Deconvolution and Normalization Algorithms Permit Seamless Resolution of
Multi-Color Images
Inter-System Reproducibility Enables Assay Standardization
EASE-OF-USE
Point and Shoot Instrumentation and Software Calibration
Intuitive Graphic Interface and Full Instrument Control with Access to Diagnostic and Data
Display Tools
Pre-Loaded ICS-501TM Image Capture Software
Data Can be Downloaded into Simple Text and Excel Files
THROUGHPUT & SPEED
Sample Loading Tray Accepts and Images up to 4 Standard 1 inch x 3 inch Slides in a
Standard Microtiter Plate Footprint
Imaging Time for a One-Color Array is Less Than 2 Minutes; For a Two-Color Array, Imaging
Time is Less Than 5 Minutes
Multiple GSD-501 Instruments can be Connected For High-Throughput Processing of Assays
SUPERIOR ACCURACY AND REPRODUCIBILITY
GSD-501 COMPARED TO FLUORESCENCE DETECTION FOR TWO-COLOR RECIPROCAL ASSAY
RLS was compared with direct fluorescent microarray detection in a
reciprocal two-color experiment, as shown in Figure 1. Spiked transcripts at
2x, 5x, and 10x relative to a 1 million copy control target were used to gauge
the differential output and sensitivity of the assay for both RLS and
fluorescence detection.
RLS Outperformed Fluorescence As Follows:
Both RLS channels effectively detected using 2x, 5x, and 10x with the
GSD-501
Cy5 detection could not be resolved at 1 million copies of control target
RLS two-color performance is based on approximately 7x more positives
than Cy5/Cy3
Reproducibility of RLS signals across the dynamic range of
the assay, as measured on 6 different GSD-501 instruments.
PRODUCT CATALOG # DESCRIPTION
GSD-501TM RLS DETECTION & IMAGING SYSTEM 50-9001-0 INCLUDES GSD-501, COMPUTER, MONITOR, GSD-501 SYSTEM CALIBRATION KIT, CABLE/POWER SUPPLY,
ICS-501TM IMAGE CAPTURE SOFTWARE, ARRAYVISIONTMRLS IMAGE ANALYSIS SOFTWARE AND 1 YEAR WARRANTY
CONTACT YOUR GENICON SCIENCES REPRESENTATIVE FOR INDIVIDUAL COMPONENT PRICING
ArrayVision is a trademark of Imaging Research, Inc. CyDye is a trademark of Amersham Biosciences. Genicon Sciences, RLS Particles, GSD-501, ICS-501 and RLSystem are trademarks of Genicon Sciences Corporation.
Copyright © 2003 Genicon Sciences. All rights reserved. 02/03
INSTRUMENTATION
TWO-COLOR PERFORMANCE COMPARISON OF GENICON SCIENCES’
GSD-501 WITH A WIDELY USED FLUORESCENT SCANNER
GSD-501 INTER-SYSTEM REPRODUCIBILITY
SLIDE SERIAL NUMBER 12365194
COPY NO. AVG. S/B STDEV %CV
HIGH 54.3 4.30 7.91
MED 28.9 2.03 7.05
LOW 4.9 0.36 7.25
SLIDE SERIAL NUMBER 12365193
COPY NO. AVG. S/B STDEV %CV
HIGH 51.3 5.04 9.83
MED 23.5 2.36 10.06
LOW 3.2 0.32 9.88
DETECTION LABELS IN THE FORMAT TITRATION/CONTROL - CONTROL
INPUT SPIKE HELD CONSTANT AT 1 MILLION COPIES
Representative images of RLS two-color detection in true color (A), Silver
after deconvolution (B), and Gold after deconvolution (C), shown in Figure 2.
The experiment maintained a 1 million copy control level for Gold detection
while titrating Silver detection to 2x, 5x, and 10x copies relative to Gold. In
RLS detection shown here, cDNA was labeled with either fluorescein or
biotin, and detected with anti-fluorescein 60 nm Silver or anti-biotin 80 nm
Gold.
THE RL SYSTEM TM
Genicon Sciences has developed a
fully integrated product portfolio of
commercially available assay toolkits,
instrumentation, and software for a
wide variety of analytical bioassays
and test formats. All products are validated
and designed for use with, or in conjunction
with RLS Technology as part of an integrated
RLSystem.
Shipping Weight 43 lbs
Warranty: 90 Day Warranty
Stock # 222211
Couldn't load pickup availability
Low stock: 1 left
View full details