PERKIN ELMER MBA 2000 UV/VIS SPECTROPHOTOMETER WATCH VIDEO FREE SHIP
PERKIN ELMER MBA 2000 UV/VIS SPECTROPHOTOMETER WATCH VIDEO FREE SHIP
This listing is for a TESTED and in PERFECT OPERATIONAL Condition PERKIN ELMER MBA 2000 UV/VIS SPECTROPHOTOMETER as can be WATCHED IN THE VIDEO and also seen in the pictures.
This system came from a Federal University and has always been very well taken care of and that's why we offer a 90-DAY-WARRANTY!
Brand new sets like these Retail new for over US$ 3.000,00 so this is the chance to buy one at a Great Deal!!!
Technical Information in Italics Blue below was taken from Manufacturer's website:
Perkin-Elmer’s Analytical Instruments Division has introduced a new productivity tool
for genetic analysis, biotechnology and pharmaceutical drug discovery research laboratories
— the Molecular Biology Assistant (MBA) 2000 system.
Every laboratory which handles or measures samples containing DNA or
proteins can benefit from the breadth of features in this development. The
MBA 2000 instrument is a truly innovative, compact computational
system which consolidates and organizes routine and customized
functions used in virtually all protocols employing biochemicals.
The new system employs an intuitive touchscreen display and has no
moving parts in a nine-inch wide, lowprofile package. Choices are made
with a touch-to-select action, and a crisp color graphics display prompts
the user as needed to complete the tasks.
The system serves the laboratory researcher every hour of the day by making
computations and quantitation extremely accessible and rapid.
Most tasks are completed in a matter of seconds.
The MBA 2000 system is designed exclusively to provide targeted and applications
specific assistance for the daily chores of the molecular biologist.
MBA 2000 - spectrometer, photometer, UV/Vis spectrometer
The MBA 2000 (Molecular Biology Assistant) from Perkin-Elmer is a compact, easy to use UV/Vis Spectrophotometer. It measures and instantly displays spectra and performs respective calculations for specific applications. The instrument uses Array Technology and measures and displays the entire UV/ Vis spectrum between 200nm and 700nm within one second. The MBA 2000 allows general spectroscopic analysis and all typical routine photometric measurements (Absorbance / Concentration...) of liquid samples in 1cm cells.
The MBA 2000 is designed for biological applications as they are frequently used in molecular biological and clinical labs. Among others this includes the quantification of Nucleic Acids, DNA purity-checks and quantification of Proteins. On top of this, it offers various calculation possibilities and lab tools for typical lab applications. Ready-to-use pre-programmed methods are available for a wide range of typical bio-applications (list of methods below). This makes the operation extremely simple and intuitive. UV/Vis Spectroscopy can't be easier and faster!
In addition to the bio-methods, the MBA 2000 includes various defined methods for any other UV/Vis application. Thus the instrument can be used in any lab for typical UV/Vis measurements. The methods include spectral scanning, concentration determination with factor or simple or complex calibration curves. A listing of the respective methods can be found below.
The MBA 2000 is the ideal UV/Vis spectrometer for routine UV/Vis application in any lab. It is also ideal for education purposes because it instantly displays the entire spectrum and allows do demonstrate all classical UV/Vis applications.
Predefined Methods for Analysis of Nucleic Acids:
Ratio 280 / 260 - for purity check of DNA
DNA & Protein Mix - for purity check of DNA and proteins
Ratio 280 / 240 - for purity check of DNA
ss DNA Concentration - for concentration-determination of single-stranded DNA
ds DNA Concentration - for concentration-determination of double-stranded DNA
RNA Concentration - for concentration-determination of RNA
Oligoquant 1 - for precise concentration-determination of Oligonucleotides based on their sequence (< 50)
Oligoquant 2 - for precise concentration-determination of Oligonucleotides based on their sequence ( > 50)
Oligo Concentration - alternative method for Oligonucleotide concentration
Primer / Probe Stock Concentration
DNA Sample Concentration
Nucleic Acid Quantitation
.... and it is possible to define and store additional methods for own applications
Pre-defined Methods for Analysis of Proteins:
Lowry Low (>20µg/mL) - for concentration-determination of protein using Lowry method
Coomassie (595nm) - for concentration-determination of protein using Coomassie staining
Bradford (1 - 1000µg/mL) - for concentration-determination of protein using Bradford method
Biuret (0.1 - 10mg/mL) - for concentration-determination of protein using Biuret method
ELISA 405 - for concentration-determination of protein in ELISA assays
BCA Assay (200 - 1200µg/mL) - for concentration-determination of protein using BCA method
DNA & Protein Mix - for purity check of DNA and proteins
HRP / TMB 450nm - for concentration-determination of protein using HRP / TMB at 450nm
ALK PHOS 492nm - for concentration-determination of protein using alkaline phosphatase at 492nm
.... and it is possible to define and store additional methods for own applications
Pre-defined Methods for general UV/Vis Analysis:
Spectral Display - recording of spectra in the wavelength range 200 - 700nm (%T)
Absorbance Scan - recording of spectra in the wavelength range 200 - 700nm (A)
UV Scan - recording of spectra in the wavelength range 200 - 400nm (A)
Absorbance Ratio - determination of the Absorbance Ratio at user-defined wavelengths
Long WL Scan - recording of spectra in the wavelength range 400 - 700nm (A)
Quantitation - For determination of concentrations of an analyte using factor or calibration curve (linear / quadratic... .)
Spectral Match
Wavelength Program - absorbance measurement at user defined wavelengths
.... and it is possible to define and store additional methods for own applications
The MBA 2000 includes a number of very useful Lab Tools, for typical lab tasks - especially targeted to the molecular biological lab.
The Options - Menu, finally allows to enter base settings and also allows to define customized methods.
Technical data:
type/type of single-beam UV/Vis spectrometer (array technology) for 1 cm cuvettes/single beam spectrometer for 1 cm cuvettes
wavelength range/wavelength range 200-700 nm
time for the spectrum/time to spectrum 2s
wavelength correctness/wavelength accuracy 2 nm
spectral bandwidth / Spectral Bandwidth 2 nm
Photometric Mode / Modes Extinction, Concentration, Transmission, Ratio / Absorbance, Concentration, Transmission, Ratio
Photometric Range 0 - 2.5 A
Voltage / Power input 110 V / 220 V
Display Touch screen, 16cm diagonal, 13 cm x 9.6 cm visible area - 6.4'' diagonal, 5.2'' x 3.6'' visible area
Size / Dimensions 350 x 220 x 100 mm
Weight / Weight 3 kg
Other (information from the previous owner):
The MBA 2000 from Perkin-Elmer is a compact, easy-to-use spectrophotometer that measures and displays a spectrum in a very short time and at the same time carries out application-related measurements. Because it uses array technology, the entire UV/Vis spectrum between 200nm and 700nm is displayed instantly. It therefore allows general spectroscopic analysis and all common photometric measurements (absorption / concentration...) of liquid samples in 1 cm cuvettes.Due to the simple operation and the measurement of the entire spectrum, the device is suitable for any UV/Vis applications in the routine laboratory as well as for research and teaching. The MBA 2000 is designed for biological applications, in particular for quantifying nucleic acids, determining DNA purity and determining protein concentrations, and also offers a wide range of calculation options and areas of application in biochemical analysis. Ready-made methods are already pre-programmed for this, which makes the application particularly easy and intuitive (list of methods below). UV/Vis spectroscopy couldn't be simpler or faster!
However, the device can also be used for all other typical UV/Vis spectroscopic applications. Ready-to-use methods are also prepared for this, which only need to be adapted for the specific application. Then spectra can be recorded quickly and easily, or concentrations can be measured (with factor or calibration curve). A list of the prepared methods is given below.
Prepared methods for nucleic acid analysis:
Ratio 280 / 260 - for determining the purity of DNA
DNA & Protein Mix - for determining the purity of DNA and proteins
Ratio 280 / 240 - for determining the purity of DNA
ss DNA Concentration - for determining the concentration of single-stranded DNA
ds DNA Concentration - for determining the concentration of double-stranded DNA
RNA Concentration - for determining the RNA concentration
Oligoquant 1 - for precisely determining the concentration of oligonucleotides based on the base sequence (< 50)
Oligoquant 2 - for precisely determining the concentration of oligonucleotides based on the base sequence (> 50)
Oligo Concentration - alternative method for determining the oligonucleotide concentration
Primer / Probe Stock Concentration
DNA Sample Concentration
Nucleic Acid Quantitation
.... and you can create and save your own methods
Prepared methods for protein analysis:
Lowry Low (>20µg/mL) - to determine the protein concentration using the Lowry method
Coomassie (595nm) - to determine the protein concentration using the Coomassie staining
Bradford (1 - 1000µg/mL) to determine the protein concentration using the Bradford method
Biuret (0.1 - 10mg/mL) for Determination of the protein concentration using the biuret method
ELISA 405 for determining the protein concentration using the in ELISA Assays
BCA Assay (200 - 1200µg/mL) for determining the protein concentration using the BCA Assay
DNA & Protein Mix - for determining the purity of DNA and proteins
HRP / TMB 450nm - for determining proteins using HRP / TMB at 450nm
ALK PHOS 492nm - for determining proteins using alkaline phosphatase at 492nm
.... and you can create and save your own methods
Prepared methods for general photometric analysis:
S pectral display - recording of spectra in the wavelength range from 200 - 700nm (%T)
absorbance scan - acquisition of spectra in the wavelength range from 200 - 700nm (A)
UV Scan - Recording of spectra in the wavelength range from 200 - 400nm (A)
Absorbance Ratio - To determine the absorption ratio at wavelengths defined by the user
Long WL Scan - Recording of spectra in the wavelength range from 400 - 700nm (A)
Quantitation - To determine the Concentration at up to 3 wavelengths using a factor or calibration curve (linear / quadratic, with / without intercept)
Spectral Match
Wavelength Program - To determine the absorption at wavelengths defined by the user
.... and you can create and save your own methods
The MBA 2000 also includes a number of very useful lab tools for performing a variety of tasks typical of any analytical laboratory.
Stock # 222909
Couldn't load pickup availability
Low stock: 1 left
View full details
