EPPENDORF BIO PHOTOMETER 6131 230, 260, 280, 320, 562,595nm 0.1nm 90DAYWARRANTY
EPPENDORF BIO PHOTOMETER 6131 230, 260, 280, 320, 562,595nm 0.1nm 90DAYWARRANTY
This listing is used For Parts Condition EPPENDORF BIO PHOTOMETER 6131 230, 260, 280, 320, 562,595nm <0.1nm as can be seen in the pictures.
Unit came from a Federal University as can be seen in the pictures.
Picture is actual item buyer will receive.
FREE USA SHIPPING ALSO!!!
TECHNICAL INFORMATION IN ITALICS BLUE BELOW WAS TAKEN FROM THE WEB:
marshallscientific.com/v/vspfiles/specs/BP%20specs.pdf
Eppendorf BioPhotometer Model #6131
The Eppendorf BioPhotometer Model #6131 is used for rapid, simple, and convenient measurement of many different research methods including measurement of nucleic acids, proteins, and bacteria density through photometric principles. The single-beam photometer with reference beam and several fixed wavelengths make this photometer extremely efficient within the lab with exceptional reliability and repeatability. The high quality components guarantee high operating reliability while the metal housing ensures operating stability.
Eppendorf BioPhotometer Model #6131 Specifications:
Photometer
Optical system: Absorption single-beam photometer with reference beam
and several fixed wavelengths
Irradiation source: Xenon flash lamp
Spectral dispersion: Holographic concave grating
Measuring wavelengths: Xe 230, 260, 280, 320, 562, 595 nm
Wavelength selection: Method-dependent, program-controlled
Spectral bandwidth: 5 nm at 230 to 320 nm
7 nm at 562 to 595 nm
Wavelength systematic error: ± 1 nm at 230 to 280 nm
± 2 nm at 320 to 595 nm
Wavelength random error: ≤ 0.1 nm
Photometric measuring range: Quartz glass cuvette: 0.000 to 3.000 A
UVette® (Eppendorf): 2.5 A at 230 nm
2.6 A at 260 nm
2.8 A at 280 nm
2.9 A at 320 nm
Photometric random error: ≤ 0.002 A at 0 A
≤ 0.005 A at 1 A
Photometric systematic error: ± 1 % at 1 A
Accuracy of reading: 0.001 A
Stray-light proportion: < 0.05 %
Radiation detector: Silicium photo diodes
Measuring procedures
Measuring procedure: End-point against blank
Method-dependent
calculation: Absorbance
Concentration via factor
Concentration via Warburg formula
Concentration via calibration with 1 to 10 standards
One-point calibration (1 standard)
Linear regression (2 to 10 standards)
Non-linear regression
(3rd degree polynomer; 4 or 5 to 10 standards;
see Section 12, "Calculation")
1 x, 2 x or 3 x determination
For nucleic acids:
Ratio 260/280
Ratio 260/230
Molar concentration
Total yield
Memory
Method memory: 12 preprogrammed, modifiable method programs
Calibration memory: For all calibration procedures
Results memory: For 100 results with absorbance and ratio values,
sample number, sample dilution, date and time (calendar up to 2090)
Used and in excellent working order.
FREE USA SHIPPING!!!!
INTERNATIONAL BUYERS PLS CONTACT US FOR SHIPPING QUOTE!!!
Stock # 231902
Couldn't load pickup availability
Out of stock
View full details
