Features
- Saturno 300 plus - is a TRUE RANDOM ACCESS CHEMISTRY ANALYZER fully computer controlled by a built-in industrial Pentium computer, where all the tests for Patient #1 are performed before starting on Patient #2 with an immediate print-out of the Patient Report.
Important: This SATURN PLUS eBay listing does not include any software nor any computer hardware such as CPUs or Printers.
- THROUGHPUT - 300 actual tests per hour independently of type or method, plus 180 electrolytes per hour at the same time. A total of 480 tests per hour.
- CAPACITY - 40 PRIMARY TUBES or small sample cups. Including 20 places reserved for Standards, Controls and STATS.
- CONTINUOUS SAMPLE LOADING and programming while the analyzer is in operation.
- UP TO 240 PATIENTS – can be programmed with continuous sample loading while the analyzer is in operation. - AUTOMATIC PRE-DILUTION of SAMPLES – if necessary.
- 60 ON-LINE Reagents, each Reagent can be cooled or left at room temperature. Four types of reagent containers: 50 – 30 – 10 and 5 ml.
- REAGENT VOLUME – is automatically monitored with an On-Line inventory. The number of tests available in each reagent container is displayed and its stability checked.
- IDENTIFICATION OF SAMPLES - with a built-in bar code reader (optional).
- IDENTIFICATION OF REAGENTS - with a built-in bar code reader (optional)
- WALK-AWAY OPERATION - Once the patients are programmed, all operations are fully automatic. The reaction cuvettes are automatically washed and dried to assure a non-stop operation.
- INCUBATION – takes place in quartz cuvettes immersed in a liquid bath at 37°C to assure perfect temperature control of the reactions.
- DIRECT READING - a built-in Multi-filter photometer measures the samples several times during its incubation at 8 different wavelengths.
- WASHING SYSTEM – includes two independent probes. This allows to have a better throughput with method with long incubation time.
- GRAPHIC DISPLAY – of calibration curves, Patient kinetic curves, Quality Control graphs, etc
-STATISTICS of tests performed
- I.S.E MODULE - to run Sodium, Potassium and Chloride simultaneously (Optional)
- AUTOMATIC REPETITION OF TESTS - results that are critical, outside linear range or due to substrate depletion are automatically pre-diluted and repeated.
- SAMPLE and REAGENT DISPENSING PROBES – have built-in Liquid Level Sensors and Mixers to assure a correct sample preparation. A special probe washing system eliminates contamination and carry over. rMAGNETIC CLAMPING OF THE PROBES - MICRO-VOLUMES OF REAGENT - a total of 300 µl of reagent is sufficient to run any test.
- WASHING SOLUTION – Its quality is automatically checked by the system
- INCUBATION SOLUTION – Its quality is automatically checked by the system.
- KEYBOARD – a full keyboard for easy programming of Patients with demographics.
- USER FRIENDLY SOFTWARE – with graphic presentation, makes it easy and simple to operate, including ON LINE - HELP program.
- OPEN SYSTEM - an unlimited number Chemistry and Immunoassay methods and profiles are all user programmable.
- ON LINE QUALITY CONTROL - checks the precision during standardization and during the daily operation.
- STATS – are processed within 6 minutes without interfering with normal routine testing.
- PATIENT REPORTS - are user personalized on an 80 column printer.
- TEST RATIOS – are user programmable
- MANUAL RESULT INPUT – for complete Patient Report Print-out
- PATIENT ARCHIVE – is stored on a 40 Gbyte hard disk, including statistics.
- REAL TIME COMMUNICATION – with host
- BI-DIRECTIONAL INTERFACE - via a built-in a RS232/C connection to EDP systems
-OPERATION Will guide the operator step by step through all operations.
- ARCHIVE To store thousands of patient data for future online consultation and to print patient reports.
METHODS To introduce an unlimited number of user programmable methods.
PROFILES To program an unlimited number of profiles or organ panels.
STANDARDS To program an unlimited number of standards, calibrators and curves.
CONTROLS To introduce and unlimited number of controls for the Quality Control program.
PARAMETERS Special personalization of ones analyzer.
MAITENANCE Online control of all operating steps and procedures in the system. Online troubleshooting
-METHODOLOGIES
- Open system, unlimited number of methods, all user programmable..
- Less than 300 µl of reagent per test.
- Automatic sample pre-dilution if necessary.
- Two reagent chemistries and immunoassays.
REAGENT CONTROL
- 60 on-line reagents individually cooled or left at room temperature.
- On-line reagent inventory and display of the numbers of test available in each of the reagent containers.
- On-line reagent stability check.
- Bar code reagent identification (optional).
PATIENT ENTRY
- 40 on-line primary tubes or sample caps with continuous sample loading and programming while analyzer is working.
- STATS will be processed within 6 minutes, without disrupting routine testing.
- Bidirectional interface enables to receive and transmit data from and to outside computer.
- Bar code reader for samples and reagents identification (optional)