CAIRN OPTOSCAN MONOCHROMATOR SYSTEM CONTROLLER 300to800nm ±0.5 nm 90DAYWARRANTY
CAIRN OPTOSCAN MONOCHROMATOR SYSTEM CONTROLLER 300to800nm ±0.5 nm 90DAYWARRANTY
This listing is for a Great Condition CAIRN OPTOSCAN MONOCHROMATOR SYSTEM CONTROLLER 300to800nm ±0.5 nm as can be seen in the pictures.
FEEL FREE TO WATCH A VIDEO OF A COMPLETE OPTOSCAN SYSTEM (THIS LISTING ONLY INCLUDES THE SYSTEM CONTROLLER OF COURSE) WORKING BY CLICKING THE FOLLOWING LINK: https://www.youtube.com/watch?v=7i2CL_x7EBo
Unit came from a Federal University and has ALWAYS been very well taken care of as can be seen in the pictures.
FULLY TESTED, WORKING PERFECTLY THAT'S WHY WE OFFER A 90-DAY-WARRANTY!!!
Picture is actual item buyer will receive.
This has been fully tested and is working perfectly and that's why we offer a 90-DAY-WARRANTY on this unit!!!
FREE USA SHIPPING ALSO!!!
TECHNICAL INFORMATION IN ITALICS BLUE BELOW WAS TAKEN FROM THE WEB:
cairn-research.co.uk/product/optoscan-monochromator/
Applications
• Fluorescence photometry
• Fluorescence imaging
• Optical scanning
Key Benefits
• Sub-millisecond control of centre wavelength with microsecond precision
• Sub-millisecond bandwidth control allows spectral and intensity optimisation at each wavelength
• Can be used with 75w lamps
• Modular design means that the light source can be removed and used independently as a white light source if required
• Light guide / fibre couplings to all popular microscopes
• External iris diaphragm for manual intensity control
• Built in fast electronic shuttering on all versions
• USB, Microprocessor, PCI, digital, and analog control option
Full Specification
• Optical configuration – enhanced Czerny-Turner configuration with fast F/2 light collection and off-axis parabolic mirrors to minimise
aberrations
• Diffraction grating – 1200 line ruled grating blazed for broad UV/visible range, 1800 and 2000 line holographic gratings for demanding
applications
• Wavelength resolution – 300-800nm specified with 0.5nm resolution @ ±1.5nm accuracy
• Bandwidth resolution – 0-30nm specified with 0.1nm resolution @ ±0.2nm accuracy
• Wavelength switching – 200nm transition <1.5ms, 50nm transitions in <1ms
• Bandwidth switching – Typical transition times of <1.5ms for both input and exit slits
• Digital shuttering (TTL) – Typically <2ms (depending on bandwidth)
Used and in excellent working order.
FREE USA SHIPPING!!!!
INTERNATIONAL BUYERS PLS CONTACT US FOR SHIPPING QUOTE!!!
Stock # 231802
Couldn't load pickup availability
Low stock: 1 left
View full details
