BECKMAN TYPE JS-7.5 AVANTI J SERIES J2 FIXED ROTOR CONICAL BUCKET 90day WARRANTY
BECKMAN TYPE JS-7.5 AVANTI J SERIES J2 FIXED ROTOR CONICAL BUCKET 90day WARRANTY
Regular price
$950.00 USD
Regular price
Sale price
$950.00 USD
Taxes included.
This listing is for a PERFECT OPERATIONAL CONDITION: BECKMAN TYPE JS-7.5 AVANTI J SERIES J2 (except Avanti J-E) FIXED ROTOR with 4 CONICAL BUCKETS as can be seen in the pictures.
COMES WITH 4 ROTOR with 4 CONICAL 3 Place 50 ml PN: 362213 Conical 50ml Tube BUCKETS.
Came from a University lab and has always been very well taken care of, that's why it is in wonderful Operational Condition.
IMPORTANT: For use with BECKMAN AVANTI J SERIES J2 (except Avanti J-E) CENTRIFUGES.
Four-place, aluminum swinging bucket rotors are for use in Avanti™ J-26 XP and XPIBK393124 series and J6-MIBK360291 centrifuges.
Applications: Initial Processing of Cells and Removal of Cell Debris from Culture Media
Space for Four up to 250 mL
Material: Aluminum
Four-Place Rotors
They are ideal for initial processing of cells and removal of cell debris from culture media.
The rotors accommodate four 250 mL tubes.
THESE BECKMAN TYPE ROTORS SELL NEW FOR OVER US$ 16.000,00 NEW
PLEASE READ ALL TECHNICAL INFORMATION BY COPYING AND GOOGLING THE FOLLOWING ONLINE LINK IN BLUE: beckman.com/centrifuges/rotors/swinging-bucket/362212
MANUFACTURER's TECHNICAL DATA SHEET ON THESE ROTORS BELOW:
Specifications:
JS-7.5 Swinging-Bucket Rotor, Aluminum, without Buckets. Major applications: Initial processing of cells and removal of cell debris from culture media.
For use in Avanti J Series centrifuges (except Avanti J-E) and J2 Series centrifuges.
Specifications
Platform Avanti
Rotor Type Swinging-Bucket (High Performance)
Maximum RPM 7,500 rpm
k-Factor 5,287
Nominal Capacity 1,000.00|mL
rMAX 165
rMIN 51
rAV 108 mm
Specification:
Maximum speed: 7500 rpm
Critical speed range: 600 to 800 rpm
Maximum solution density: 1.2 g/mL
Relative Centrifugal Field at maximum speed
Using buckets (r max 165 mm): 10400 x g
Using 3 x 50-mL carriers (r max 168 mm): 10580 x g
Using 4 x 50-mL carriers (r max 160 mm): 10080 x g
Using 24 x 5-mL carriers (r max 142 mm): 8950 x g
k factor at maximum speed (full tubes)
In 250-mL buckets: 5287
in 3 × 50-mL multitube carriers: 4140
in 4 × 50-mL multitube carriers: 3959
in 24 × 5-mL multitube carriers: 2818
Number of buckets/carriers: 4
Nominal bucket capacity: 200 mL
Nominal carrier capacity (4 x 50-mL carrier): 800 mL
Nominal rotor capacity: 1 liter
Rotor weight, maximum sample mass: 10-9 kg (24 lb)
Approximate acceleration time to maximum speed (rotor fully loaded) in an Avanti J-25 centrifuge: 1 minute
Approximate deceleration time to maximum speed (rotor fully loaded) in an Avanti J-25 centrifuge: 1 minute
Approximate acceleration time to maximum speed (rotor fully loaded) in a J2 series centrifuge: 4 minutes
Approximate deceleration time to maximum speed (rotor fully loaded) in a J2 series centrifuge: 3 ½ minutes
Rotor yoke material: aluminum, painted
Bucket and multitube carrier material: aluminum, anodized
Package Quantity 1
The rotor is in EXCELENT OPERATIONAL CONDITION with normal cosmetic wear as can be seen in the pictures.
Please see the photos for more detail.
Testing
We have tested the rotor with an AVANTI J2 centrifuge and can guarantee that the condition is exactly as described.
Stock # 19204