APPLIED BIOSYSTEMS 7900HT PCR/THERMAL CYCLER FAST REAL TIME PCR SYSTEM FREE SHIP
APPLIED BIOSYSTEMS 7900HT PCR/THERMAL CYCLER FAST REAL TIME PCR SYSTEM FREE SHIP
This listing is for a WONDERFUL WORKING CONDITION APPLIED BIOSYSTEMS 7900HT PCR/THERMAL CYCLER FAST REAL TIME PCR SYSTEM as can be seen in the pictures.
DOES INCLUDE and come with the Manuals and all the Extras you see in the pictures!!!
IMPORTANT: NO SOFTWARE IS INCLUDED WITH THIS UNIT! This unit came from a Federal University, has been fully tested and is Guaranteed Working Perfectly and that's why we offer a 90-DAY-WARRANTY!
TECHNICAL DATA SHEET CAN BE FOUND BY GOOGLING THE FOLLOWING LINK: thermofisher.com/document-connect/document-connect.html?url=https://assets.thermofisher.com/TFS-Assets%2FLSG%2...
INFORMATION IN ITALICS BLUE BELOW WAS TAKEN FROM THE WEB, we do not abide by the information below in Italics Blue, we only copied it from the web for buyer to check if this is the unit he is looking for. There may be accessories included in the italics blue information below which are not part of this listing, ONLY what is in the pictures is what we are selling here on eBay, if you don't see it then it is NOT included!
Applied Biosystems 7900HT PCR/Thermal Cycler FAST Real-Time PCR System RT-PCR
The 7900HT Fast Real-Time PCR System is a real-time quantitative PCR system that combines 96- and 384-well plate compatibility and the TaqMan™ Low Density Array with fully automated robotic loading-and now also offers optional Fast real-time PCR capability.
• Fast PCR option reduces run time to about 35 minutes in a standard 96-well format, or about 55 minutes in a 384-well plate.
• Continuous wavelength detection from 500-660 nm allows the use of multiple fluorophores in a single reaction.
• Measure gene expression levels, detect and quantitate pathogens, perform allelic discrimination (SNP genotyping) assays as well as score the presence of gene sequences.
• 96- or 384-well plate compatibility (including the TaqMan™ Low Density Array).
• Optional Enterprise edition software provides data analysis tools that support 21 CFR Part 11 guidelines providing data integrity and security.
• Hands-free plate-loading and unloading provides true walkaway automation allowing you to increase your lab's productivity.
• Proven assay development guidelines save time and money
High Throughput
The 7900HT System is a high-throughput real-time PCR system that detects and quantitates nucleic acid sequences. An Automation Accessory combined with 384-well plate capability make the 7900HT system ideally suited to meet the high-throughput requirements of today's drug discovery process. Key applications include gene expression quantitation and the detection of single nucleotide polymorphisms (SNPs) using the fluorogenic 5' nuclease assay.
Flexibility
The 7900HT system is a versatile research tool that can accommodate any real-time PCR need. User-interchangeable thermal cycling block formats let you select the format that’s right for your project, using industry-standard 96- and 384-well formats, as well as a novel 384-well TaqMan™ Low Density Array and a new Fast 96-well block that reduces run times from 2 hours to about 30 minutes. An easy automation upgrade path lets you add features to meet throughput demands. A Fast PCR option reduces run times from 2 hours to about 30 minutes.
Specifications
Calibrated Dye
SYBR™ Green I, ROX™, NED™, JOE™, TAMRA™, VIC™, FAM™, TET™
Capacity
Up to 84 x 384-well plates (with optional automation accessory and 384-well block), Up to 36 x 96-well plates with optional automation accessory
Detection Method
SYBR, Primer-Probe Detection
Block Format
Interchangeable
Includes
1- Instrument with Fast 96-Well Block Module
Reaction Speed
Fast
Dynamic Range
Up to 9 logs of linear dynamic range
Format
96-well plate
For Use With (Equipment)
7900HT Fast System
High-throughput Compatibility
High-throughput Compatible, Multiplexing
Optics
Extended-life 488 nm argon-ion laser excitation source, No filters (CCD acts as spectrograph with continuous detection 500 -650 nm)
Passive Reference Dye
ROX (Separate Tube), No ROX, Other Passive Reference Dye, ROX (Pre-mixed)
Reaction Volume Range
10-30 µl
Run Time
33 minutes (96-well in fast mode)
Sample Ramp Rate
Fast mode: ± 3.0°C⁄sec, Standard mode: ± 1.6°C⁄sec
Sensitivity
Down to 10 copies
Temperature Accuracy
±0.25°C of display temperature
Temperature Range (Metric)
4-100°C
Temperature Uniformity
±0.5°C
Thermal Cycling System
Peltier-Based System
Throughput
≥5,000 real-time PCR rxns per day (384-well block and automation accessory), ≥10,000 endpoint PCR rxns per hour (384-well block and automation accessory)
Dimensions
72 cm (W) x 84 cm (D) x 64 cm (H) (with drawer open)
Weight
114 kg (250 lbs) with automation accessory, 82 kg (180 lbs) without automation accessory.
Software Download:SDS V2.4.1 Installation Instruction(English) by GOOGLING the following link: thermofisher.com/document-connect/document-connect.html?url=https://assets.thermofisher.com/TFS-Assets%2FLSG%2...
Stock # 222209
Couldn't load pickup availability
Out of stock
View full details